Bioreactor Minifor -
Advantages of Minifor Bioreactor for cell culture
New improvements in cell culture:
Easy sterility: Elimination of critical points makes the keeping of bioreactor sterility
easy. A strong silicone membrane isolates completely the vessel from the environment.
The sterility is equivalent to magnetic coupling but is considerably less complex
and much less expensive. All o-



Adapter for very sensitive cells: A spiral covered by a thin wall of air containing
silicone tubing is fixed on the axis of the stirrer. The up and down movement of
the spiral displaces oxygen saturated layers of the culture and simultaneously produces
a gentle movement of the medium. Because oxygen saturated layers in the proximity
of the gas supplying tubing are removed fast, the moving spiral system is more efficient
than common stationary systems.
Radiation heating: The infrared radiation concentrated
on the bottom of the vessel produces extremely gentle and regular sun like heating
of the culture! It produces natural convection even without agitation. No hot spots
are formed at any culture volume. Thanks to the very low heat capacity of the radiator,
the temperature can be attained in a short time and can easily be kept constant.
Furthermore the sight into the vessel is not hindered.
Culture volumes from 35 ml
to 6000 ml: A broad volume spectrum is possible with just one bioreactor. Since no
expensive top plates are used, the cost of passing from one volume vessel to another
is several times lower than in other systems.
MINIFOR is very compact: The MINIFOR
is the most compact bioreactor available. Nevertheless, the ports are well accessible
from all sides.
Fastest set up: Special system and vessel construction of MINIFOR
Bioreactor allows the fastest set up when compared to all other systems on the market.
Fully
automatic gas flow: Lambda discarded all rotameters and manual valves on so called
four gas stations. Their reading is pressure and temperature dependent and cannot
be well reproduced. Additionally, they cannot be automatically regulated and do not
supply any recordable signal. A new gas flow meter and controller MASSFLOW has been
developed. The gas flow measurement is based upon the precise massflow principle
and is unaffected by pressure and temperature variations. It supplies a high quality
signal, which is used to control our proprietary proportional valve for a precise
regulation of the gas flow rate. The gas volume can be measured, totalised and recorded
for the control of metabolic activity of the culture.
Automatic pH and pO2 control:
The carbon dioxide regulating MASSFLOW instrument is just plugged into the acid pump
socket on the rear of the MINIFOR Bioreactor and if necessary the nitrogen regulating
MASSFLOW to the base pump socket. The MINIFOR Bioreactor will keep both pH and pO2
on the preset value automatically.
Self-
Continuous culture: The weight of MINIFOR can be kept constant by using
a special weighing module placed under the front edge of bioreactor. The harvesting
pump will keep automatically the volume of the culture constant. Continuous cultures
allow a considerable increase of productivity.
INTEGRATOR: When the integrator is
switched to pumps or MASSFLOW gas flow regulator, their activity can be followed
as a function of time. The data obtained in this way give additional information
about the culture; it's growth kinetics and reproducibility.
PC control: Easy to use,
complete software FNet for up to six MINIFOR Bioreactor units.
All these features
result in a dramatic improvement of the cell culture, precise control of preset parameters
and their easy documentation.